Eaton Metered Input rack PDU, 0U, L6-30P input, 5.76 kW max, 200-240V, 24A, 10 ft cord, Single-phase, Outlets: (36) C13 Outlet grip, (6) C19 Outlet grip - NEMA L6-30P - 36 x IEC 60320 C13, 6 x IEC 60320 C19 - 230 V AC - 5760 W - Network (RJ-45) - 38U - Ra
Eaton G3 Metered Input ePDUs provide a best-in-class design featureing billing grade accuracy monitoring of input and branch circuits on a local LCD pixel display or over a network connection. The high accuracy meter will measure current, voltage, power and energy for load balancing, capacity planning, efficiency monitoring and energy usage reporting. Designed for IT and data center applications means high reliability and a robust design made for high operating temperatures found in containment or networking closets.
- IEC outlet grip plug retention secures plugs in place using standard cables
- Advanced LCD pixel display for local display of current, voltage, power, energy and menu setup of parameters such as IP address or display rotation
- High operating temperature (140F / 60C) for containment or hot network closet environments
- Hot-swap meter for servicability of without removing power to the rack
- +/- 1% billing grade accuracy for high accuracy reporting of energy usage
- Daisy chain of IP addresses allows four devices to share one network connection
$631.98 -
Eaton Metered Input rack PDU, 0U, 309-360P6W input, 11.5 kW max, 200-240V, 48A, 6 ft cord, Single-phase, Outlets: (30) C13 Outlet grip, (6) C19 Outlet grip - 30 x IEC 60320 C13, 6 x IEC 60320 C19 - 230 V AC - 11.50 kW - Network (RJ-45) - 38U - Vertical -
Eaton Metered Input ePDUs
Learn More
Eaton Metered Input ePDUs provide remote monitoring of the current draw of individual sections via network communication. This capability, combined with state-of-the-art software allows you to aggregate the information from many ePDUs in one location. A local display is also available for phase balancing and for easy start-up and provisioning of servers. New ePDU G3 Metered Input models feature best-in-class technologies, including ±1% billing grade accuracy, an advanced LCD pixel display, a hot-swap meter and the ability to daisy chain four ePDUs to share the same network connection and IP address.$1,644.09 -
Eaton Metered Input rack PDU, 0U, L6-30P input, 5.76 kW max, 200-240V, 24A, 15 ft cord, Single-phase, Outlets: (24) C13, (6) C19 - NEMA L6-30P - 24 x IEC 60320 C13, 6 x IEC 60320 C19 - 0U - Rack-mountable
Eaton Metered Input ePDUs provide remote monitoring of the current draw of individual sections via network communication. This capability, combined with state-of-the-art software allows you to aggregate the information from many ePDUs in one location. A local display is also available for phase balancing and for easy start-up and provisioning of servers. New ePDU G3 Metered Input models feature best-in-class technologies, including ±1% billing grade accuracy, an advanced LCD pixel display, a hot-swap meter and the ability to daisy chain four ePDUs to share the same network connection and IP address.
Learn More$1,102.90 -
Eaton Metered Input rack PDU, 0U, L5-30P input, 2.88 kW max, 120V, 24A, 10 ft cord, Single-phase, Outlets: (24) 5-20R - NEMA L5-30P - 2880 W - 36U - Rack-mountable
Eaton Metered Input ePDUs provide remote monitoring of the current draw of individual sections via network communication. This capability, combined with state-of-the-art software allows you to aggregate the information from many ePDUs in one location. A local display is also available for phase balancing and for easy start-up and provisioning of servers. New ePDU G3 Metered Input models feature best-in-class technologies, including ±1% billing grade accuracy, an advanced LCD pixel display, a hot-swap meter and the ability to daisy chain four ePDUs to share the same network connection and IP address.
Learn More$1,000.88 -
Eaton ePDU IPC3402-3880 PDU - NEMA L5-30P - 8 x NEMA 5-15R - 120 V AC - 2880 W - Network (RJ-45) - 10 ft Cord Length - 1U - Horizontal - Rack-mountable
Eaton ePDU IPC3402-3880 PDU - NEMA L5-30P - 8 x NEMA 5-15R - 120 V AC - 2880 W - Network (RJ-45) - 10 ft Cord Length - 1U - Horizontal - Rack-mountable Learn More$984.53 -
Eaton Powerware ePDU 4-Outlets 5.76kVA PDU - 4 x NEMA L6-30R - 5.76kVA - Zero U Rack-mountable
Eaton Powerware ePDU 4-Outlets 5.76kVA PDU - 4 x NEMA L6-30R - 5.76kVA - Zero U Rack-mountable Learn More$420.85